Data Centers and Groundwater

Part 2. Industry drive manufacturers can play a part in keeping data centers cool and the digital world going.
By Brett Mernin
Data centers seem to be in the news daily. Due to their large energy demands and often corresponding water quantity needs, questions about groundwater availability are common. Water Well Journal launched a three-part series on the topic in the January issue and this is the second installment. We’ll conclude next month in the March issue. —Thad Plumley, WWJ Editor
The digital world we live in today is built on data. From search engines and streaming services to artificial intelligence and cloud computing, almost everything we use to work and relax relies on the smooth, secure operation of data centers.
As essential as these technologies are, the sheer processing power required to run today’s applications generates an immense amount of heat. To keep servers functioning at peak performance, effective cooling isn’t just important, it’s critical.
Cooling a data center is no small task. It demands a blend of high-efficiency solutions that can balance energy use, system reliability, operational agility, and long-term cost management. An astonishing 40% of a data center’s total power consumption is used for cooling, and as sites expand in both size and processing capacity, the need for smarter, more sustainable cooling methods grows even more urgent.
At the heart of these advanced cooling solutions is drive technology: specifically, variable frequency drives (VFDs) paired with high-performance motors, fans, compressors, and pumps that deliver dynamic, responsive operation.
Drive specialists offer a combination of global reach, innovative technology, and manufacturing capability ensuring they deliver exactly what data center operators need. From fast and flexible solutions to highly energy-efficient cooling systems designed to meet the rising demands of today’s digital economy, they have the expertise and resources to help build the data centers of the future.
The evolution of data center cooling

Forty percent (40%) of a data center’s power is used for cooling, and industry manufacturers of drives, motors, compressors, and pumps are positioned to help achieve that.
Traditionally, data centers cooled their server rooms using conventional air conditioning systems like those used in commercial buildings. Air-cooled units drew heat away from server racks, expelled the heat outdoors, and cycled cooler air back in.
While effective for smaller loads, this approach has struggled to keep pace with the explosive growth of computing power, especially with the rise of artificial intelligence and big data applications. Today’s servers are densely packed and perform far more calculations per second than ever before, leading to dramatically higher power consumption and—as a result—heat generation.
Modern cooling strategies now combine air cooling with water-based solutions. Water cooling, particularly through cold plates attached directly to processors, offers much higher thermal transfer rates than air alone. Some technologies are even embracing the concept of immersion cooling, where the server components are fully submerged in non-conductive cooling fluids such as specially engineered dielectric liquids that offer exceptional heat transfer.
No matter the method, moving heat efficiently still depends on one key factor: the drives and controls of the pumps, compressors, and fans used within the systems.
Why drives matter more than ever
Fixed-speed motors, the traditional workhorses of cooling systems, can seem to have several advantages to offer, including low upfront costs. However, this design is inherently inefficient. These motors run at full capacity regardless of actual cooling demand, leading to excessive energy consumption, especially during off-peak periods when cooling needs are significantly lower.
VFDs change that equation. By adjusting motor speeds to match real-time cooling demands, VFDs drastically reduce power consumption. Pumps only move as much water as is needed, and fans only run fast enough to maintain optimal temperatures.
This dynamic control has several critical advantages:
- Energy savings: Reducing motor speeds even slightly can slash energy consumption by 30% to 50%.
- Extended equipment life: Motors and mechanical components experience less wear and tear.
- Precision cooling: Fine-tuned systems can maintain ideal server conditions, boosting performance and uptime.
- Lower operating costs: Less energy use and fewer repairs deliver meaningful bottom-line savings.
For data centers, where thousands of motors might be running 24/7, the impact is massive. Every percentage point of efficiency gained translates into significant financial and environmental returns.
A complete solution for data center cooling
Data center cooling isn’t about relying on a single piece of technology, but the synergy between multiple components. Motors, pumps, compressors, drives, and control systems all need to work in perfect harmony to deliver the precise and efficient cooling that high-performance data centers demand.
Most industry drive manufacturers offer a comprehensive suite of technologies that integrate seamlessly to support every stage of the cooling process. Examples include:
- High-efficiency pump control technology: Built to handle the pressures of continuous operation, drives offer dependable flow and pressure control for high-precision performance for water-cooled and hybrid cooling systems. Their reliability and energy-conscious
design make them ideal for the demands of modern data centers. - High performance compressor control: Whether you’re using traditional refrigerant-based
methods or implementing more progressive free-cooling strategies, control architecture provides the consistency and flexibility required to manage heat loads effectively. Drives are engineered for optimal thermal exchange with an eye on long-term efficiency. - Cutting-edge industrial drives: VFDs are designed for real-time responsiveness. They empower
facility managers to dial in cooling outputs with remarkable precision, adapting to fluctuating
data loads without wasting energy. From startups to hyperscale centers, VFDs scale to meet a
range of operational needs for everything from fans to full-scale cooling towers.
The benefits are clear: simplified installation, reduced engineering complexity, streamlined maintenance, all through a single flexible drive platform.
Global reach, local responsiveness
In a world where downtime isn’t just inconvenient but potentially catastrophic, having a supply partner that can deliver quickly and consistently makes all the difference.
The cooling needs of data centers will only grow as computing power and demand continue to rise. Water cooling will become standard. Immersion cooling will shift from early adoption to everyday application. And cooling towers—already critical in large-scale operations—will continue to evolve for even higher efficiency.
But no matter how technology advances, one principle remains unchanged: Moving heat takes energy.
Managing that energy with intelligence and precision is the key to long-term success.
The article details how the centers use millions of gallons of water for cooling, which could strain local resources. It adds, however, that there are some hydrogeologic approaches that could conserve water, including managed aquifer recharge and geothermal systems which haven’t received as much attention but show potential.
The growth of the internet, artificial intelligence, and cloud computing is resulting in rapid growth in data centers across the country. There is a growing concern about the resources these installations require to operate and the long-term impacts those demands might have on the surrounding areas. Groundwater professionals can play critical roles in addressing water availability and the impacts of data center water use on local resources.
The National Ground Water Association formed a Data Center Task Force to provide a forum for discussing data center issues and best practices to meet water needs. NGWA members who were interested in participating in the task force met on December 11 during Groundwater Week 2025 in New Orleans to develop initial ideas for the group. A white paper and position paper are envisioned as key initial products of the Task Force.
NGWA members who are interested in participating should contact NGWA Director of Science and Technology Bill Alley, Ph.D., at walley@ngwa.org.
Brett Mernin is director of strategic marketing focusing on motors, drives, and drive solutions at Nidec Drives, part of Nidec Motor Corp. He can be contacted at brett.mernin@mail.nidec.com.
you might also like
The acquisition is the latest step in Xylem’s ongoing portfolio transformation.
Click here to learn more about this workshop, Digitization of [...]